Salvum ac solatium sub pedibus SPC Tabulatum

Salvum ac solatium sub pedibus SPC Tabulatum

Descriptio:

Item:TYM506

Crassitudo;4.0mm~8.0mm
Gere, Stratum:0.2mm~0.7mm
Substratum (Libitum)EVA/IXPE, 1.0mm~2.0mm
Magnitudo12" X 24"/ 12" X 12"/ Customization

tub_4 tub_5tub_7tub_1

Cum upgrade versionis LVT TABULATIO, SPC Tabulatum magis magisque populare in foro contignatione facta est, non solum propter singularem aquae probationem, sed etiam propter praestantes eius notas in vetustate.Facile est ponere, Eco-amice, super-fortis skip-resistentes, chemicae resistentia cum coloribus et speciebus copiosissimis.Sine dubio in multis locis nunc late fiebat una ex calidissimis contignationibus.


Product Detail

Product Detail:

dd4c2fd0

Una ex rebus magicis SPC tabulatis pro nostris consumptoribus est quod, sive flabella vultus lapidea es sive potius aspectus lignorum, semper in SPC tabulatum ventus exemplar obtinere potuisti, vel etiam magnus es flabella lapidea. vide laterem, sed admiratio calida et commoda calcatis, SPC Tabulatum uno tempore satisfacere potest.Eligite SPC tabulam sicut tabulatum domus tuae, spatium proprium tuum, evadit tibi sapiens idea, quia unum facile est invenire unum exemplar populare quod maxime cupis, cum finiri non potest. fit cogitare de toto genere cubiculi tui, cum milia exemplarium popularium in promptu, non difficile sit tibi unum par cum idea tua, etiam de speciali tui spatii ratione, invenire.Cum suo proprio pluma in pedibus, tutum adhuc molliorem et commodorem affectum sub pedibus dat, frigus et durum non senties, etiam cum tabulatum subis, est splendidis lapis aspectus.SPC Tabulatum, non solum tibi salutem et commodam calcaribus praebet, sed etiam multis modis tibi satisfacit, sicut eius eximiam et copiosam aspectum eligere potes.

tub_2

Specification

Superficiem textura

Lignum Texture

altiore Crassitudo

4mm

Substratum (Libitum)

IXPE/EVA (1mm/1.5mm)

gere Stratum

0.2mm.(8 Mil.)

Latitudo

12» (305mm).

Longitudo

24 (610mm.)

perago

UV Coating

Obstructio Ratio

tub_6

Applicationem

Commercial & Residential

 

Technical data:

tub_9SPC RIGID-CORE PLANK ARTI DATA

Technical Information

Test Methodi

Proventus

Dimensional

EN427 &
ASTM F2421

Transi

Crassitudo in total

EN428 &
ASTM E 648-17a

Transi

Crassitudo lapsum stratis

EN429 &
ASTM F410

Transi

Dimensional Stability

IOS 23999:2018 & ASTM F2199-18

Vestibulum Directio ≤0.02% (82oC @ 6hrs)

Trans Manufacture Directio ≤0.03% (82oC @ 6hrs)

Flexilis (mm)

IOS 23999:2018 & ASTM F2199-18

Precium 0.16mm(82oC @ 6hrs)

Peel Strength (N/25mm)

ASTM D903-98(2017)

Vestibulum Directio 62 (Mediocris)

Per Directio Fabrica LXIII (Mediocris)

Static Load

ASTM F970-17

Residua Indentation: 0.01mm

RELICTUM Indentation

ASTM F1914-17

Transi

Repugnantia scabere

ISO 1518-1:2011

Non penetravit membrana ad onus 20N

Obfirmo Fortitudo (kN / m)

ISO 24334:2014

Vestibulum Directio 4.9 kN/m

Per Directio Fabrica 3.1 kn/m

Color Ieiunium ut lux

ISO 4892-3:2016 Cycle 1 & ISO105–A05:1993/Cor.2:2005& ASTM D2244-16

≥ 6

Reactionem igni

BS EN14041:2018 Clause 4.1 & EN 13501-1:2018

Bfl-S1

ASTM E648-17a

Classis 1

ASTM E 84-18b

Classis A

VOC Emissions

BS EN 14041:2018

ND - Pass

ROHS/Metal!

EN 71-3:2013+A3:2018

ND - Pass

pervenire

No 1907/2006 PERVENIO

ND - Pass

Formaldehyde emissio

BS EN14041:2018

Classis: E 1

Phthalate Test

BS EN 14041:2018

ND - Pass

PCP

BS EN 14041:2018

ND - Pass

Donec adipiscing Elementorum

EN 71 – 3:2013

ND - Pass

Stipare Information

Stipare Information (4.0mm)

Pcs/ctn

12

Pondus (KG) / ctn

22

Ctns / grabatum

60

Plt/20'FCL

18

Mq/20'FCL

3000

Pondus (KG) / GW

24500


  • Priora:
  • Deinde:

  • Epistulam tuam hic scribe et mitte nobis